Send Message
Home ProductsAtomic Absorption Spectrometer

Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb

I'm Online Chat Now

Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb

Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb
Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb

Large Image :  Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb

Product Details:
Place of Origin: Shanghai, China
Brand Name: PEAK INSTRUMENTS
Model Number: AA3018
Payment & Shipping Terms:
Minimum Order Quantity: 1 unit
Price: $10,500.00 - $16,000.00/units
Packaging Details: Carton Box
Supply Ability: 100 Unit/Units per Month

Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb

Description
Warranty: 1 Year And Extendable Customized Support: OEM, ODM
Size: 82*68*55CM Weight: 88KG
Focal Length: 350mm Wavelength Range: 190-900nm
Optical Type: Single Beam Slits: 0.1/0.2/0.4/0.7/1.4/2.0 Nm
Detector: Photomultiplier Tube Lamp Holder: Automated 8-lamp Turret
Background Correction: Deuterium Background Correction Grating: 1800lines/nm
Wavelength Accuracy: ±0.2nm Reading Mode: T A C
Temperature Range: Ambient-3000℃ Heating Rate: 1-225s

Product Description
Product Name
Single Beam Graphite furnace Atomic Absorption Spectrometer
Origin
China
Brand
PEAK INSTRUMENTS
Model
AA3018
Wavelength range
190-900nm
Grating 
Holographic diffraction grating with 1800 lines/mm
Monochromator
Czerny-Turner type with focal lengths at 350mm
Detector
UV Sensitive Photomultiplier Tube
Slits
0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm
Lamp Holder
Automated 8-Lamp Turret
Photometric Range
0-125%, -0.1-3.00A
Reading Mode
Transmittance, Absorbance, Concentration
Back Ground Correction
Deterium (D2) Lamp Back Ground Correction
Software
RGWIN AAS software
Power Supply
110/220V, 50/60Hz
Packing Dimension
101*78*83cm, 128kgs.
Our Advantages
Quality
1. Our products have good quality and very positive reputations in the market. 
2. Customers are very happy with them and have a lot of good comments about our intruments and service.
Delivery Time
1. We can get them ready 3-5 days after order confirmation for small orders. 
2. For big quantities, need to be confirmed.
3. In most cases, fast delivery is guaranteed.
Technical Support
1. We have service manual. If not, detailed documents or videos will be provided.
2. We can provide online or site training in our factory.
3. We can have video conference at any time.
Aftersales Support
1. Respond to your questions within 10 minutes during our working time from 6:30 to 24:00, at most within 8 hours after 24:00 considering the time difference.
2. Within warranty, we will solve the problem for you with no charge(except for consumables).
3. You can call, text or email us at any time. We have good English speakers.
Warranty Time
One year and extendable
Our product advantages are as follws:
Why Choose Us
Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb 0
1. Positive comments from our Italian client
Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb 1
2. Good review from our customer in Italy
Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb 2
3. Great comments from Syria client
Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb 3
4. UAE customer is satified with our pH meter
Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb 4
5. Argentina customer is happy with our pH meters
Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb 5
6. Turkey user is satisfied with its performance of spectrophotometer
Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb 6
7. Spain customer is very happy with our fast service and professional technical support
Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb 7
8. Indian client is happy with our great support
Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb 8
9. Peru customer likes our spectrophotometer very much
Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb 9
10. Salvador customer has good comments on our pH meter
Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb 10
11. South Africa customer is happy with the accuracy of our spectrophotometer and pH meter
Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb 11
12. Customer in Poland said our products are very good
Certifications
Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb 12

CE

ISO 9001 and ISO14001 are also available
Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb 13

CE ANNEX

Customer Photos
Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb 14
Customer visit and training
Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb 15
Visit cutomers and have a training
Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb 16
Customer from Brazil
Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb 17
Visit and train customers in Chile
Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb 18
Training
Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb 19
Customer from Argentina
Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb 20
Clients from Korea
Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb 21
Distributor from Thailand
FAQ
Q: What areas and applications can it be used?
A: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.
Q: Does it need any installation
A: The installation is very simple, just need to connect it to power supply and turn it on, then you can use it.
Q: What standard accessories are included?
A: Main unit, 1cm cell holder(4 positions for single beam and 2 positions for double beam), 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1 cm quartz cuvette(UV models), one USB with user manual and power cable.
Q: Is PC software included?
A: The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.
Q: Why the reading is red and reach its maximum value 3.00Abs?
A: Probably you use the glass cuvette in UV range.
Q: Why the wavelength calibration or self checking fail?
A: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.
Q: Why is the reading is not as accurate as before?
A: Do the wavelength calibration before testing or restore the device to its default factory settings.
Q: Why PC software can not be installed successfully?
A: Close your anti-virus software on the computer and do it again.
Q: Why the software can not be connected successfully?
A: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.
Q: Can the data transferred to USB or PC?
A: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.
Q: Why the Abs value is negative(lower than zero).
A: Do the blanking or change the reference sample.
Exhibition
Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb 22
Analytica in Germany
Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb 23
Pittcon in USA
Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb 24
ArabLab in Dubai
Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb 25
IndiaLabExpo in India
Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb 26
Analytica Lab Africa
Customized ODM Support AA3018 Graphite Furnace AAS 190-900nm Wavelength Range for Pb 27
Analitica Latin America in Sao Paulo, Brazil

Contact Details
PEAK Instruments (Shanghai) Co., Ltd.

Contact Person: Mr. Feng

Tel: +86 13402095836

Send your inquiry directly to us (0 / 3000)