±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam ±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam ±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam ±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam ±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam ±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam

Large Image :  ±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam

Product Details:
Place of Origin: Shanghai, China
Brand Name: PEAK INSTRUMENTS
Model Number: C-7200100
Payment & Shipping Terms:
Minimum Order Quantity: 1 unit
Price: $2,138.00/units 1-9 units
Packaging Details: Carton Box

±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam

Description
Warranty: 3 Years Customized Support: OEM, ODM
Size: 61*46*24CM Weight: 23KG
Focal Length: Null Wavelength Range: 190-1100nm
Display: 7 Inch LCD Screen Optical System: Double Beam, Holographic Grating (1200 Lines/mm)
Spectral Bandwidth: 2nm Wavelength Accuracy: ±0.3nm
Wavelength Repeatability: ≤0.2nm Stray Light: ≤0.05%T@220, 360nm
Baseline Flatness: ±0.002A Noise: 0.0003@500nm
Detector: Solid Silicon Photodiode Light Source: Deuterium/Tungsten Lamp

Product Description
Product Name
Double beam 190-1100nm UV Visible 2nm Spectrophotometer
Origin
China
Brand
PEAK INSTRUMENTS
Model
C-7200100
Functions
Photometry, quantitative measurement, kinetics, multiwavelength test, wavelength scanning, DNA/Protein test on standalone device
PC Software
Optional
Size
61*46*24CM
Weight
23KG
Wavelength range
190-1100nm
Display
7 inch LCD screen
Optical System
Double beam, Holographic Grating (1200 Lines/mm)
Spectral Bandwidth
2nm
Wavelength Accuracy
±0.3nm
Wavelength Repeatability
≤0.2nm
Stray Light
≤0.05%T@220, 360nm
Baseline Flatness
±0.002A
Noise
0.0003@500nm
Detector
Solid Silicon Photodiode
Data Export
USB(A) for date transfer, USB(B) for PC software, RS232 for optional printer
Light Source
Deuterium/Tungsten Lamp
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 0
1. Photometry Measurements
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 1
2. Quantitative Test
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 2
3. Kinetics Measurement(time scanning)
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 3
4. Wavelength Scanning
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 4
5. Multiwavelength Test
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 5
6. DNA/Protein measurement
Our Advantages
Quality
1. Our products have good quality and very positive reputations in the market. 
2. Customers are very happy with them and have a lot of good comments about our intruments and service.
Delivery Time
1. We can get them ready 3-5 days after order confirmation for small orders. 
2. For big quantities, need to be confirmed.
3. In most cases, fast delivery is guaranteed.
Technical Support
1. We have service manual. If not, detailed documents or videos will be provided.
2. We can provide online or site training in our factory.
3. We can have video conference at any time.
Aftersales Support
1. Respond to your questions within 10 minutes during our working time from 6:30 to 24:00, at most within 8 hours after 24:00 considering the time difference.
2. Within warranty, we will solve the problem for you with no charge(except for consumables).
3. You can call, text or email us at any time. We have good English speakers.
Warranty Time
One year and extendable
Our product advantages are as follws:
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 6
1. 7 inch color LCD screen(button models) can show more parameters
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 7
2. Silicone buttons with much longer life span and easier to be operated
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 8
2. 7 inch capacitive touch screen and user friendly interface
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 9
4. Standard USB ports for data transfer and PC software connection.
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 10
5. More functions for basic models
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 11
6. Stable system with microcomputer processing
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 12
7. Automatic 8 position 1 cm cell holder(optional)
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 13
8. Long path cell holder can holde 1-10cm cuvettes(optional)
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 14
9. Tube rack for tubes with 16mm diameters(optional for all models)
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 15
10. Film cell holder(optional for all models)
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 16
11. Automatic sampler/sipper system(optional)
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 17
12. PC software, thermal printer, etc.
Why Choose Us
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 18
1. Positive comments from our Italian client
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 19
2. Good review from our customer in Italy
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 20
3. Great comments from Syria client
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 21
4. UAE customer is satified with our pH meter
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 22
5. Argentina customer is happy with our pH meters
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 23
6. Turkey user is satisfied with its performance of spectrophotometer
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 24
7. Spain customer is very happy with our fast service and professional technical support
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 25
8. Indian client is happy with our great support
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 26
9. Peru customer likes our spectrophotometer very much
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 27
10. Salvador customer has good comments on our pH meter
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 28
11. South Africa customer is happy with the accuracy of our spectrophotometer and pH meter
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 29
12. Customer in Poland said our products are very good
Certifications
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 30

CE

ISO 9001 and ISO14001 are also available
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 31

CE ANNEX

Product process
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 32
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 33
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 34
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 35
1.Install main board
2.Connect the cables for main board
3.Install W1 lamp and D2 lamp
4.Assemble sample chamber and cell holder
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 36
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 37
5.Install power board
6.Assemble monochromator
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 38
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 39
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 40
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 41
7.Upload software
8.Adjust and test W1 lamp and D2 lamp
9.System test
10.Housing installation and final calibration
Customer Photos
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 42
Customer visit and training
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 43
Visit cutomers and have a training
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 44
Customer from Brazil
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 45
Visit and train customers in Chile
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 46
Training
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 47
Customer from Argentina
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 48
Clients from Korea
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 49
Distributor from Thailand
FAQ
Q: What areas and applications can it be used?
A: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.
Q: Does it need any installation
A: The installation is very simple, just need to connect it to power supply and turn it on, then you can use it.
Q: What standard accessories are included?
A: Main unit, 1cm cell holder(4 positions for single beam and 2 positions for double beam), 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), one USB with user manual and power cable.
Q: Is PC software included?
A: The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.
Q: Why the reading is red and reach its maximum value 3.00Abs?
A: Probably you use the glass cuvette in UV range.
Q: Why the wavelength calibration or self checking fail?
A: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.
Q: Why is the reading is not as accurate as before?
A: Do the wavelength calibration before testing or restore the device to its default factory settings.
Q: Why PC software can not be installed successfully?
A: Close your anti-virus software on the computer and do it again.
Q: Why the software can not be connected successfully?
A: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.
Q: Can the data transferred to USB or PC?
A: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.
Q: Why the Abs value is negative(lower than zero).
A: Do the blanking or change the reference sample.
Exhibition
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 50
Analytica in Germany
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 51
Pittcon in USA
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 52
ArabLab in Dubai
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 53
IndiaLabExpo in India
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 54
Analytica Lab Africa
±0.002A Baseline Flatness Quartz Cuvettes For Spectrophotometer in UV-vis Double Beam 55
Analitica Latin America in Sao Paulo, Brazil

Contact Details
PEAK Instruments (Shanghai) Co., Ltd.

Contact Person: Mr. Feng

Tel: +86 13402095836

Send your inquiry directly to us (0 / 3000)