Send Message
Home ProductsUV Visible Spectrophotometer

190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement

I'm Online Chat Now

190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement

190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement

Large Image :  190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement

Product Details:
Place of Origin: China
Brand Name: PEAK INSTRUMENTS
Certification: CE,ISO
Model Number: C-7200108
Payment & Shipping Terms:
Minimum Order Quantity: 1 unit
Price: $2,715.00/units >=1 units

190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement

Description
Warranty: 3 Year Customized Support: OEM, ODM
Size: 61*46*24CM Weight: 23KG
Focal Length: Null Wavelength Range: 190-1100nm
Type: Raman Spectrometer, Fluorescence Spectrophotometer Display: 7 Inch LCD Screen
Optical System: Double Beam, Holographic Grating (1200 Lines/mm) Spectral Bandwidth: 2nm
Wavelength Accuracy: 0.3nm Wavelength Repeatability: ≤0.2nm
Baseline Flatness: 0.002A Detector: Solid Silicon Photodiode
Light Source: Deuterium/Tungsten Lamp

Product Description
Product Name
Double beam 190-1100nm UV Visible 2nm Spectrophotometer
Origin
China
Brand
PEAK INSTRUMENTS
Model
C-7200108
Functions
Photometry, quantitative measurement, kinetics, multiwavelength test, wavelength scanning, DNA/Protein test on standalone device
PC Software
Optional
Size
61*46*24CM
Weight
23KG
Wavelength range
190-1100nm
Display
7 inch LCD screen
Optical System
Double beam, Holographic Grating (1200 Lines/mm)
Spectral Bandwidth
2nm
Wavelength Accuracy
±0.3nm
Wavelength Repeatability
≤0.2nm
Stray Light
≤0.05%T@220, 360nm
Baseline Flatness
±0.002A
Noise
0.0003@500nm
Detector
Solid Silicon Photodiode
Data Export
USB(A) for date transfer, USB(B) for PC software, RS232 for optional printer
Light Source
Deuterium/Tungsten Lamp
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 0
1. Photometry Measurements
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 1
2. Quantitative Test
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 2
3. Kinetics Measurement(time scanning)
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 3
4. Wavelength Scanning
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 4
5. Multiwavelength Test
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 5
6. DNA/Protein measurement
Our Advantages
Quality
1. Our products have good quality and very positive reputations in the market. 
2. Customers are very happy with them and have a lot of good comments about our intruments and service.
Delivery Time
1. We can get them ready 3-5 days after order confirmation for small orders. 
2. For big quantities, need to be confirmed.
3. In most cases, fast delivery is guaranteed.
Technical Support
1. We have service manual. If not, detailed documents or videos will be provided.
2. We can provide online or site training in our factory.
3. We can have video conference at any time.
Aftersales Support
1. Respond to your questions within 10 minutes during our working time from 6:30 to 24:00, at most within 8 hours after 24:00 considering the time difference.
2. Within warranty, we will solve the problem for you with no charge(except for consumables).
3. You can call, text or email us at any time. We have good English speakers.
Warranty Time
One year and extendable
Our product advantages are as follws:
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 6
1. 7 inch color LCD screen(button models) can show more parameters
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 7
2. Silicone buttons with much longer life span and easier to be operated
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 8
2. 7 inch capacitive touch screen and user friendly interface
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 9
4. Standard USB ports for data transfer and PC software connection.
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 10
5. More functions for basic models
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 11
6. Stable system with microcomputer processing
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 12
7. Automatic 8 position 1 cm cell holder(optional)
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 13
8. Long path cell holder can holde 1-10cm cuvettes(optional)
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 14
9. Tube rack for tubes with 16mm diameters(optional for all models)
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 15
10. Film cell holder(optional for all models)
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 16
11. Automatic sampler/sipper system(optional)
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 17
12. PC software, thermal printer, etc.
Why Choose Us
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 18
1. Positive comments from our Italian client
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 19
2. Good review from our customer in Italy
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 20
3. Great comments from Syria client
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 21
4. UAE customer is satified with our pH meter
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 22
5. Argentina customer is happy with our pH meters
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 23
6. Turkey user is satisfied with its performance of spectrophotometer
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 24
7. Spain customer is very happy with our fast service and professional technical support
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 25
8. Indian client is happy with our great support
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 26
9. Peru customer likes our spectrophotometer very much
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 27
10. Salvador customer has good comments on our pH meter
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 28
11. South Africa customer is happy with the accuracy of our spectrophotometer and pH meter
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 29
12. Customer in Poland said our products are very good
Certifications
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 30

CE

ISO 9001 and ISO14001 are also available
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 31

CE ANNEX

Product process
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 32
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 33
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 34
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 35
1.Install main board
2.Connect the cables for main board
3.Install W1 lamp and D2 lamp
4.Assemble sample chamber and cell holder
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 36
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 37
5.Install power board
6.Assemble monochromator
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 38
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 39
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 40
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 41
7.Upload software
8.Adjust and test W1 lamp and D2 lamp
9.System test
10.Housing installation and final calibration
Customer Photos
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 42
Customer visit and training
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 43
Visit cutomers and have a training
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 44
Customer from Brazil
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 45
Visit and train customers in Chile
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 46
Training
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 47
Customer from Argentina
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 48
Clients from Korea
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 49
Distributor from Thailand
FAQ
Q: What areas and applications can it be used?
A: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.
Q: Does it need any installation
A: The installation is very simple, just need to connect it to power supply and turn it on, then you can use it.
Q: What standard accessories are included?
A: Main unit, 1cm cell holder(4 positions for single beam and 2 positions for double beam), 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), one USB with user manual and power cable.
Q: Is PC software included?
A: The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.
Q: Why the reading is red and reach its maximum value 3.00Abs?
A: Probably you use the glass cuvette in UV range.
Q: Why the wavelength calibration or self checking fail?
A: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.
Q: Why is the reading is not as accurate as before?
A: Do the wavelength calibration before testing or restore the device to its default factory settings.
Q: Why PC software can not be installed successfully?
A: Close your anti-virus software on the computer and do it again.
Q: Why the software can not be connected successfully?
A: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.
Q: Can the data transferred to USB or PC?
A: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.
Q: Why the Abs value is negative(lower than zero).
A: Do the blanking or change the reference sample.
Exhibition
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 50
Analytica in Germany
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 51
Pittcon in USA
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 52
ArabLab in Dubai
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 53
IndiaLabExpo in India
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 54
Analytica Lab Africa
190-1100nm Double Beam UV/Vis Spectrophotometer for Accurate Wavelength Measurement 55
Analitica Latin America in Sao Paulo, Brazil

Contact Details
PEAK Instruments (Shanghai) Co., Ltd.

Contact Person: Mr. Feng

Tel: +86 13402095836

Send your inquiry directly to us (0 / 3000)