Send Message
Home ProductsUV Visible Spectrophotometer

ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range

I'm Online Chat Now

ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range

ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range

Large Image :  ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range

Product Details:
Place of Origin: Shanghai, China
Brand Name: PEAK INSTRUMENTS
Model Number: E1000UV
Payment & Shipping Terms:
Minimum Order Quantity: 1 unit
Price: $285.00/units 1-9 units
Packaging Details: Carton Box
Supply Ability: 1000 Unit/Units per Month

ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range

Description
Warranty: 1 Year And Extendable Customized Support: OEM, ODM
Size: 44*36*18CM Weight: 6.5KG
Focal Length: Null Wavelength Range: 190-1020nm
Display: 40*70mm Backlit LCD Optical System: Single Beam, Holographic Grating (1200 Lines/mm)
Spectral Bandwidth: 4 Nm Wavelength Accuracy: ±2nm
Wavelength Repeatability: ≤1nm Stray Light: ≤0.15%T@360nm
Baseline Flatness: Null Noise: Null
Detector: Solid Silicon Photodiode Light Source: Deuterium/Tungsten Lamp

Product Description
Product Name
4nm single beam UV Visible Cheap spectrophotometer
Origin
China
Brand
PEAK INSTRUMENTS
Model
E1000UV
Function
Photometry, quantitative measurement on standalone device.
Working Mode
T, A, C, F
Size
44*36*18CM
Weight
6.5KG
Focal length
null
Wavelength range
190-1020nm
Display
40*70mm backlit LCD
Optical System
Single beam, Holographic Grating (1200 Lines/mm)
Spectral Bandwidth
4 nm
Wavelength Accuracy
±2nm
Wavelength Repeatability
≤1nm
Stray Light
≤0.15%T@360nm
Detector
Solid Silicon Photodiode
Light Source
Deuterium/Tungsten Lamp
Our Advantages
Quality
1. Our products have good quality and very positive reputations in the market. 
2. Customers are very happy with them and have a lot of good comments about our intruments and service.
Delivery Time
1. We can get them ready 3-5 days after order confirmation for small orders. 
2. For big quantities, need to be confirmed.
3. In most cases, fast delivery is guaranteed.
Technical Support
1. We have service manual. If not, detailed documents or videos will be provided.
2. We can provide online or site training in our factory.
3. We can have video conference at any time.
Aftersales Support
1. Respond to your questions within 10 minutes during our working time from 6:30 to 24:00, at most within 8 hours after 24:00 considering the time difference.
2. Within warranty, we will solve the problem for you with no charge(except for consumables).
3. You can call, text or email us at any time. We have good English speakers.
Warranty Time
One year and extendable
Our product advantages are as follws(for high end models):
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 0
1. 7 inch color LCD screen(button models) can show more parameters
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 1
2. Silicone buttons with much longer life span and easier to be operated
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 2
2. 7 inch capacitive touch screen and user friendly interface
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 3
4. Standard USB ports for data transfer and PC software connection.
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 4
5. More functions for basic models
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 5
6. Stable system with microcomputer processing
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 6
7. Automatic 8 position 1 cm cell holder(optional)
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 7
8. Long path cell holder can holde 1-10cm cuvettes(optional)
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 8
9. Tube rack for tubes with 16mm diameters(optional for all models)
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 9
10. Film cell holder(optional for all models)
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 10
11. Automatic sampler/sipper system(optional)
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 11
12. PC software, thermal printer, etc.
Why Choose Us
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 12
1. Positive comments from our Italian client
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 13
2. Good review from our customer in Italy
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 14
3. Great comments from Syria client
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 15
4. UAE customer is satified with our pH meter
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 16
5. Argentina customer is happy with our pH meters
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 17
6. Turkey user is satisfied with its performance of spectrophotometer
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 18
7. Spain customer is very happy with our fast service and professional technical support
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 19
8. Indian client is happy with our great support
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 20
9. Peru customer likes our spectrophotometer very much
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 21
10. Salvador customer has good comments on our pH meter
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 22
11. South Africa customer is happy with the accuracy of our spectrophotometer and pH meter
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 23
12. Customer in Poland said our products are very good
Certifications
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 24

CE

ISO 9001 and ISO14001 are also available
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 25

CE ANNEX

Product process
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 26
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 27
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 28
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 29
1.Install main board
2.Connect the cables for main board
3.Install W1 lamp and D2 lamp
4.Assemble sample chamber and cell holder
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 30
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 31
5.Install power board
6.Assemble monochromator
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 32
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 33
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 34
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 35
7.Upload software
8.Adjust and test W1 lamp and D2 lamp
9.System test
10.Housing installation and final calibration
Customer Photos
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 36
Customer visit and training
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 37
Visit cutomers and have a training
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 38
Customer from Brazil
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 39
Visit and train customers in Chile
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 40
Training
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 41
Customer from Argentina
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 42
Clients from Korea
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 43
Distributor from Thailand
FAQ
Q: What areas and applications can it be used?
A: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.
Q: Does it need any installation
A: The installation is very simple, just need to connect it to power supply and turn it on, then you can use it.
Q: What standard accessories are included?
A: Main unit, 1cm cell holder(4 positions for single beam and 2 positions for double beam), 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), one USB with user manual and power cable.
Q: Is PC software included?
A: The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.
Q: Why the reading is red and reach its maximum value 3.00Abs?
A: Probably you use the glass cuvette in UV range.
Q: Why the wavelength calibration or self checking fail?
A: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.
Q: Why is the reading is not as accurate as before?
A: Do the wavelength calibration before testing or restore the device to its default factory settings.
Q: Why PC software can not be installed successfully?
A: Close your anti-virus software on the computer and do it again.
Q: Why the software can not be connected successfully?
A: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.
Q: Can the data transferred to USB or PC?
A: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.
Q: Why the Abs value is negative(lower than zero).
A: Do the blanking or change the reference sample.
Exhibition
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 44
Analytica in Germany
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 45
Pittcon in USA
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 46
ArabLab in Dubai
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 47
IndiaLabExpo in India
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 48
Analytica Lab Africa
ODM Customized Support UV Visible Spectrophotometer with 190-1020nm Wavelength Range 49
Analitica Latin America in Sao Paulo, Brazil

Contact Details
PEAK Instruments (Shanghai) Co., Ltd.

Contact Person: Mr. Feng

Tel: +86 13402095836

Send your inquiry directly to us (0 / 3000)