Send Message
Home ProductsVisible Spectrophotometer

Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth

I'm Online Chat Now

Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth

Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth

Large Image :  Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth

Product Details:
Place of Origin: Shanghai, China
Brand Name: PEAK INSTRUMENTS
Model Number: C-7000V
Payment & Shipping Terms:
Minimum Order Quantity: 1 unit
Price: $891.00/units 1-9 units
Packaging Details: Carton Box
Supply Ability: 200 Unit/Units per Month

Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth

Description
Warranty: 1 Year Customized Support: OEM, ODM
Size: 53*41*25CM Weight: 13KG
Focal Length: Null Wavelength Range: 320-1100nm
Display: 7 Inch LCD Screen Optical System: Single Beam, Holographic Grating (1200 Lines/mm)
Spectral Bandwidth: 2nm Wavelength Accuracy: ±0.3nm
Wavelength Repeatability: ≤0.2nm Stray Light: ≤0.05%T@220, 360nm
Baseline Flatness: ±0.002A Noise: 0.0005@500nm
Detector: Solid Silicon Photodiode Light Source: Tungsten Lamp

Product Description
Product Name
Single beam Visible 2nm Spectrophotometer
Origin
China
Brand
PEAK INSTRUMENTS
Model
C-7000V
Size
53*41*25CM
Weight
13KG
Wavelength range
320-1100nm
Display
7 inch LCD screen
Optical System
Single beam, Holographic Grating (1200 Lines/mm)
Spectral Bandwidth
2nm
Wavelength Accuracy
±0.3nm
Wavelength Repeatability
≤0.2nm
Stray Light
≤0.05%T@220, 360nm
Baseline Flatness
±0.002A
Noise
0.0003@500nm
Detector
Solid Silicon Photodiode
Light Source
Tungsten Lamp
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 0
1. Photometry Measurements
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 1
2. Quantitative Test
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 2
3. Kinetics Measurement(time scanning)(software extended funtion)
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 3
4. Wavelength Scanning(software extended funtion)
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 4
5. Multiwavelength Test(software extended funtion)
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 5
6. DNA/Protein measurement(software extended funtion)
Our Advantages
Quality
1. Our products have good quality and very positive reputations in the market. 
2. Customers are very happy with them and have a lot of good comments about our intruments and service.
Delivery Time
1. We can get them ready 3-5 days after order confirmation for small orders. 
2. For big quantities, need to be confirmed.
3. In most cases, fast delivery is guaranteed.
Technical Support
1. We have service manual. If not, detailed documents or videos will be provided.
2. We can provide online or site training in our factory.
3. We can have video conference at any time.
Aftersales Support
1. Respond to your questions within 10 minutes during our working time from 6:30 to 24:00, at most within 8 hours after 24:00 considering the time difference.
2. Within warranty, we will solve the problem for you with no charge(except for consumables).
3. You can call, text or email us at any time. We have good English speakers.
Warranty Time
One year and extendable
Our product advantages are as follws:
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 6
1. 7 inch color LCD screen(button models) can show more parameters
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 7
2. Silicone buttons with much longer life span and easier to be operated
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 8
2. 7 inch capacitive touch screen and user friendly interface
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 9
4. Standard USB ports for data transfer and PC software connection.
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 10
5. More functions for basic models
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 11
6. Stable system with microcomputer processing
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 12
7. Automatic 8 position 1 cm cell holder(optional)
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 13
8. Long path cell holder can holde 1-10cm cuvettes(optional)
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 14
9. Tube rack for tubes with 16mm diameters(optional for all models)
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 15
10. Film cell holder(optional for all models)
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 16
11. Automatic sampler/sipper system(optional)
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 17
12. PC software, thermal printer, etc.
Why Choose Us
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 18
1. Positive comments from our Italian client
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 19
2. Good review from our customer in Italy
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 20
3. Great comments from Syria client
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 21
4. UAE customer is satified with our pH meter
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 22
5. Argentina customer is happy with our pH meters
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 23
6. Turkey user is satisfied with its performance of spectrophotometer
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 24
7. Spain customer is very happy with our fast service and professional technical support
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 25
8. Indian client is happy with our great support
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 26
9. Peru customer likes our spectrophotometer very much
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 27
10. Salvador customer has good comments on our pH meter
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 28
11. South Africa customer is happy with the accuracy of our spectrophotometer and pH meter
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 29
12. Customer in Poland said our products are very good
Certifications
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 30

CE

ISO 9001 and ISO14001 are also available
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 31

CE ANNEX

Product process
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 32
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 33
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 34
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 35
1.Install main board
2.Connect the cables for main board
3.Install W1 lamp and D2 lamp
4.Assemble sample chamber and cell holder
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 36
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 37
5.Install power board
6.Assemble monochromator
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 38
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 39
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 40
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 41
7.Upload software
8.Adjust and test W1 lamp and D2 lamp
9.System test
10.Housing installation and final calibration
Customer Photos
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 42
Customer visit and training
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 43
Visit cutomers and have a training
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 44
Customer from Brazil
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 45
Visit and train customers in Chile
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 46
Training
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 47
Customer from Argentina
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 48
Clients from Korea
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 49
Distributor from Thailand
FAQ
Q: What areas and applications can it be used?
A: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.
Q: Does it need any installation
A: The installation is very simple, just need to connect it to power supply and turn it on, then you can use it.
Q: What standard accessories are included?
A: Main unit, 1cm cell holder(4 positions for single beam and 2 positions for double beam), 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), one USB with user manual and power cable.
Q: Is PC software included?
A: The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.
Q: Why the reading is red and reach its maximum value 3.00Abs?
A: Probably you use the glass cuvette in UV range.
Q: Why the wavelength calibration or self checking fail?
A: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.
Q: Why is the reading is not as accurate as before?
A: Do the wavelength calibration before testing or restore the device to its default factory settings.
Q: Why PC software can not be installed successfully?
A: Close your anti-virus software on the computer and do it again.
Q: Why the software can not be connected successfully?
A: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.
Q: Can the data transferred to USB or PC?
A: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.
Q: Why the Abs value is negative(lower than zero).
A: Do the blanking or change the reference sample.
Exhibition
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 50
Analytica in Germany
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 51
Pittcon in USA
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 52
ArabLab in Dubai
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 53
IndiaLabExpo in India
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 54
Analytica Lab Africa
Lab Testing Visible Spectrophotometer with ±0.3nm Wavelength Accuracy and 2nm Bandwidth 55
Analitica Latin America in Sao Paulo, Brazil

Contact Details
PEAK Instruments (Shanghai) Co., Ltd.

Contact Person: Mr. Feng

Tel: +86 13402095836

Send your inquiry directly to us (0 / 3000)