Send Message
Home ProductsVisible Spectrophotometer

Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer

I'm Online Chat Now

Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer

Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer

Large Image :  Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer

Product Details:
Place of Origin: Shanghai, China
Brand Name: PEAK INSTRUMENTS
Model Number: E-1000V100
Payment & Shipping Terms:
Minimum Order Quantity: 1 unit
Price: $214.00/units 2-9 units
Packaging Details: Carton Box

Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer

Description
Warranty: 1 Year And Extendable Customized Support: OEM, ODM
Size: 44*36*18CM Weight: 6.5KG
Focal Length: Null Wavelength Range: 320-1020nm
Display: 40*70mm Backlit LCD Optical System: Single Beam, Holographic Grating (1200 Lines/mm)
Spectral Bandwidth: 4 Nm Wavelength Accuracy: ±2nm
Wavelength Repeatability: ≤1nm Stray Light: ≤0.15%T@360nm
Baseline Flatness: Null Noise: Null
Detector: Solid Silicon Photodiode Light Source: Deuterium/Tungsten Lamp

Product Description
Product Name
4nm single beam Visible Cheap spectrophotometer
Origin
China
Brand
PEAK INSTRUMENTS
Model
E-1000V100
Function
Photometry, quantitative measurement on standalone device.
Working Mode
T, A, C, F
Size
44*36*18CM
Weight
6.5KG
Focal length
null
Wavelength range
320-1020nm
Display
40*70mm backlit LCD
Optical System
Single beam, Holographic Grating (1200 Lines/mm)
Spectral Bandwidth
4 nm
Wavelength Accuracy
±2nm
Wavelength Repeatability
≤1nm
Stray Light
≤0.15%T@360nm
Detector
Solid Silicon Photodiode
Light Source
Tungsten Lamp
Our Advantages
Quality
1. Our products have good quality and very positive reputations in the market. 
2. Customers are very happy with them and have a lot of good comments about our intruments and service.
Delivery Time
1. We can get them ready 3-5 days after order confirmation for small orders. 
2. For big quantities, need to be confirmed.
3. In most cases, fast delivery is guaranteed.
Technical Support
1. We have service manual. If not, detailed documents or videos will be provided.
2. We can provide online or site training in our factory.
3. We can have video conference at any time.
Aftersales Support
1. Respond to your questions within 10 minutes during our working time from 6:30 to 24:00, at most within 8 hours after 24:00 considering the time difference.
2. Within warranty, we will solve the problem for you with no charge(except for consumables).
3. You can call, text or email us at any time. We have good English speakers.
Warranty Time
One year and extendable
Our product advantages are as follws(for high end models):
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 0
1. 7 inch color LCD screen(button models) can show more parameters
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 1
2. Silicone buttons with much longer life span and easier to be operated
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 2
2. 7 inch capacitive touch screen and user friendly interface
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 3
4. Standard USB ports for data transfer and PC software connection.
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 4
5. More functions for basic models
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 5
6. Stable system with microcomputer processing
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 6
7. Automatic 8 position 1 cm cell holder(optional)
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 7
8. Long path cell holder can holde 1-10cm cuvettes(optional)
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 8
9. Tube rack for tubes with 16mm diameters(optional for all models)
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 9
10. Film cell holder(optional for all models)
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 10
11. Automatic sampler/sipper system(optional)
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 11
12. PC software, thermal printer, etc.
Why Choose Us
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 12
1. Positive comments from our Italian client
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 13
2. Good review from our customer in Italy
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 14
3. Great comments from Syria client
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 15
4. UAE customer is satified with our pH meter
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 16
5. Argentina customer is happy with our pH meters
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 17
6. Turkey user is satisfied with its performance of spectrophotometer
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 18
7. Spain customer is very happy with our fast service and professional technical support
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 19
8. Indian client is happy with our great support
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 20
9. Peru customer likes our spectrophotometer very much
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 21
10. Salvador customer has good comments on our pH meter
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 22
11. South Africa customer is happy with the accuracy of our spectrophotometer and pH meter
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 23
12. Customer in Poland said our products are very good
Certifications
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 24

CE

ISO 9001 and ISO14001 are also available
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 25

CE ANNEX

Product process
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 26
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 27
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 28
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 29
1.Install main board
2.Connect the cables for main board
3.Install W1 lamp and D2 lamp
4.Assemble sample chamber and cell holder
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 30
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 31
5.Install power board
6.Assemble monochromator
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 32
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 33
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 34
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 35
7.Upload software
8.Adjust and test W1 lamp and D2 lamp
9.System test
10.Housing installation and final calibration
Customer Photos
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 36
Customer visit and training
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 37
Visit cutomers and have a training
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 38
Customer from Brazil
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 39
Visit and train customers in Chile
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 40
Training
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 41
Customer from Argentina
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 42
Clients from Korea
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 43
Distributor from Thailand
FAQ
Q: What areas and applications can it be used?
A: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.
Q: Does it need any installation
A: The installation is very simple, just need to connect it to power supply and turn it on, then you can use it.
Q: What standard accessories are included?
A: Main unit, 1cm cell holder(4 positions for single beam and 2 positions for double beam), 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), one USB with user manual and power cable.
Q: Is PC software included?
A: The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.
Q: Why the reading is red and reach its maximum value 3.00Abs?
A: Probably you use the glass cuvette in UV range.
Q: Why the wavelength calibration or self checking fail?
A: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.
Q: Why is the reading is not as accurate as before?
A: Do the wavelength calibration before testing or restore the device to its default factory settings.
Q: Why PC software can not be installed successfully?
A: Close your anti-virus software on the computer and do it again.
Q: Why the software can not be connected successfully?
A: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.
Q: Can the data transferred to USB or PC?
A: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.
Q: Why the Abs value is negative(lower than zero).
A: Do the blanking or change the reference sample.
Exhibition
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 44
Analytica in Germany
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 45
Pittcon in USA
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 46
ArabLab in Dubai
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 47
IndiaLabExpo in India
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 48
Analytica Lab Africa
Single Beam Visible 320-1000nm Wavelength Range Chemistry Analyzer Spectrophotometer 49
Analitica Latin America in Sao Paulo, Brazil

Contact Details
PEAK Instruments (Shanghai) Co., Ltd.

Contact Person: Mr. Feng

Tel: +86 13402095836

Send your inquiry directly to us (0 / 3000)